4500 Series Electrified Mortise

4500 Electrified Mortise

To order, please click here to be redirected to the product page and choose the electrified option required from the menu.

ADA Compliant: True
BHMA Certified: True
UL C/US Listed: True
Contact Hager for Price

Specifications

Applications

Heavy Duty Commercial

Certifications
  • ANSI/BHMA A156.3-2014 Grade 1
  • UL305 Listed for Panic Hardware
  • UL/cUL Listed for up to 3 hours for "A" labeled doors
  • UL10C Positive Pressure Rated
  • UL10B Neutral Pressure Rated
  • Complies with ANSI 117.1 for accessible buildings and facilities
Cover

Stainless steel, zinc

Cover Tube
Aluminum
Door Thickness

1-3/4"

Door Width
  • 36" (914mm) field sizeable to 30" (762mm) panic-rated door and 28" (711 mm) fire-rated door for devices with any monitoring switches or EU/EL
  • 48" (1219mm) field sizeable to 36" (914mm) panic- or fire-rated door for devices with any monitoring switches or EU/EL
  • 36” (914mm) field sizeable to 34” (864mm) door minimum for devices with motorized electric latch retraction
  • 36” (914mm) door minimum for devices with alarm kit, delayed egress or onboard delayed egress
  • 48” (1219mm) field sizeable to 42” (1067mm) door minimum for devices with alarm kit
  • 48” (1219mm) field sizeable to 40” (1016mm) door minimum for devices with motorized electric latch retraction
  • 48” (1219mm) door minimum for devices with delayed egress or onboard delayed egress
Electric Modifications
  • RX - Request to Exit
  • RX2 - Dual Request to Exit
  • EU/EL - Electrically unlocked / Electrically locked
  • ALK - Alarm Kit
  • MLR - Motor Driven Electric Latch Retraction
  • MLRX- Motor Driven Electric Latch Retraction with Request to Exit
  • DE - Delayed Egress
  • OBDE - Onboard Delayed Egress
Electrical Specifications
  • RX; 125 VAC (3 AMP current); 30 VDC (2 AMP current)
  • MLR; 1 AMP in rush @ 24 VDC +/- 2 V
  • DE; 430mA @ 24V Single; 680mA @ 24V Tandem
  • OBDE; 540mA @ 24V Single; 790mA @ 24V Tandem
  • EU/EL; 12 Volt or 24 Volt; 250mA inrush, 10mA holding
End Caps
  • Standard end cap (zinc)
  • OPTIONAL Flush end cap (zinc)
Fasteners
  • Wood and machine screws,
  • Thru-bolts
Finishes
  • US3, US4, US10B, US26, US26D, US32D, BLK
  • Trim is not available in US32D
Notes

Recommended to be used on appropriately reinforced doors

Push Bar
OPTIONAL Photoluminescent push bar cover available
Trim
  • Archer, August, William or Withnell lever with escutcheon (3902, 1-5/8" cylinder with standard cam sold separately)
  • Mortise cylinder (1-3/8") with cylinder collar (11/16") x optional pull
  • Mortise trim (45MB, 45MC, 45MD, 45MN) does not match center line of other 4500, Series trim ( 45BE, 45CE, 45DT, 45NL)
Warranty
  • One year on electrified components
  • Lifetime on hardware components
Wire Requirements
  • Status switches (i.e. RX, LM, etc.) require 2 wires per switch to monitor a normally open (NO) or normally closed (NC) position
  • All devices provide 3 wires per switch so both NO and NC positions can be monitored
  • Monitoring both positions will require 3 wires per switch
Dogging
  • Hex key dogging standard on panic rated devices
  • Cylinder dogging available on panic rated devices, specify "CD" ( 3902 1-1/8" (29mm), mortise cylinder sold separately)
Latchbolt Type

3/4" (19 mm) throw with anti-friction tongue, all stainless steel with auxiliary deadlocking latch

Projection
  • 3" (76mm) in undogged position
  • 2-5/8" (67mm) in electrically dogged position
Stile Width
  • 4-1/2" (114mm)
  • All stile widths are measure from the door edge
Strikes
  • 4-7/8" (124mm) ASA strike-standard
  • Stainless steel with plated rollers included standard with panic devices