4500 Series Electrified Rim

4500 Electrified Rim

To order, please click here to be redirected to product page and choose the electrified option required from the menu.

ADA Compliant: True
BHMA Certified: True
UL C/US Listed: True
Contact Hager for Price

Specifications

Applications

Heavy Duty Commercial

Certifications
  • ANSI/BHMA A156.3-2014 Grade 1
  • UL305 Listed for Panic Hardware
  • UL/cUL Listed for up to 3 hours for "A" labeled doors
  • UL10C Positive Pressure Rated
  • UL10B Neutral Pressure Rated
  • Warnock Hersey listed for up to 3 hours with fire rated removable mullion
  • Complies with ANSI 117.1 for accessible buildings and facilities
  • Miami-Dade County, Florida NOA #22-0816.08, Exp. Aug. 16, 2027
Cover

Stainless steel, zinc

Cover Tube
Aluminum
Door Thickness

1-3/4" (44mm) - Standard up to 3", except with night latch which is 2-1/2"

Door Width
  • 36" (914mm) field sizeable to 30" (762mm) panic-rated door and 28" (711mm) fire-rated door for devices with any monitoring switches
  • 48" (1219mm) field sizeable to 36" (914mm) panic- or fire-rated door for devices with any monitoring switches
  • 36” (914mm) field sizeable to 34” (864mm) door minimum for devices with motorized electric latch retraction
  • 36” (914mm) door minimum for devices with alarm kit, delayed egress or onboard delayed egress
  • 48” (1219mm) field sizeable to 42” (1067mm) door minimum for devices with alarm kit
  • 48” (1219mm) field sizeable to 40” (1016mm) door minimum for devices with motorized electric latch retraction
  • 48” (1219mm) door minimum for devices with delayed egress or onboard delayed egress
Electric Modifications
  • RX - Request to Exit
  • RX2 - Dual Request to Exit
  • ALK - Alarm Kit
  • AI - Authorized Ingress
  • LM - Latchbolt Monitor
  • RXLM - Request to Exit with Latchbolt Monitor
  • MLR - Motor Driven Electric Latch Retraction
  • MLRX- Motor Driven Electric Latch Retraction with Request to Exit
  • MLRXLM - Motor Driven Electric Latch Retraction with Request to Exit and Latchbolt Monitoring
  • MLRLM - Motor Driven Electric Latch Retraction with Latchbolt Monitoring
  • DE - Delayed Egress
  • OBDE - Onboard Delayed Egress
Electrical Specifications
  • RX, LM or AI; 125 VAC (3 AMP current); 30 VDC (2 AMP current)
  • MLR; 1 AMP in rush @ 24 VDC +/- 2 V
  • DE; 430mA @ 24V Single; 680mA @ 24V Tandem
  • OBDE; 540mA @ 24V Single; 790mA @ 24V Tandem
End Caps
  • Standard end cap (zinc)
  • OPTIONAL Flush end cap (zinc)
Fasteners
  • Wood and machine screws
  • Thru-bolts
Finishes
  • US3, US4, US10B, US26, US26D, US32D, BLK
  • Trim is not available in US32D
Latchbolt Type

3/4" (19 mm) throw, pullman type with automatic dead-latching, stainless steel

Notes

Recommended to be used on appropriately reinforced doors

Push Bar
OPTIONAL Photoluminescent push bar cover available
Trim
  • Archer, August, Charles, Johnston, Joshua, Louis, Warren, William or Withnell lever with escutcheon
  • Pull plate trim
  • Rim cylinder x optional pull
Warranty
  • One year on electrified components
  • Lifetime on hardware components
Wire Requirements
  • Status switches (i.e. RX, LM, etc.) require 2 wires per switch to monitor a normally open (NO) or normally closed (NC) position
  • All devices provide 3 wires per switch so both NO and NC positions can be monitored
  • Monitoring both positions will require 3 wires per switch
Dogging
  • Hex key dogging standard on panic rated devices
  • Cylinder dogging available on panic rated devices, specify "CD" ( 3902 1-1/8" (29mm) mortise cylinder sold separately)
Projection
  • 3" (76 mm) in undogged position
  • 2-5/8" (67 mm) in electrically dogged position
Stile Width
  • 5-3/8" (137 mm) - Minimum stile width required for single doors and standard 5/8" (16 mm) stop
  • 4-7/8'' (124 mm) - Minimum stile width required for double door x surface vertical rod with double door strike
  • 5-3/4" (146 mm) - Minimum stile width required for double door and 2" (51 mm) mullion
  • 5" (127mm) - Minimum stile width required for double doors with a middle rail and a 2" mullion
  • All stile widths are measured from the door edge
Strikes
  • Stainless steel with plated rollers - Included standard with panic devices
  • Solid stainless steel - Included standard with fire-rated devices
  • Surface applied to frame with slotted holes for easy adjustment
  • Double door strike for use with surface vertical rod and rim device available