29T4

29T4
Contact Hager for Price

Specifications

Applications

Most preferred method to keep HS4 control units and power supply organized and secured in a single location

Certifications
  • CE approved
  • UL294 Listed - Access Control System Units
Environment
  • Wall mount for indoor use
  • Operating temperature: 32°F to 120°F
  • Storage temperature: -4°F to 158°F
  • 16 AWB powder-coated steel enclosure
  • Single 1.5" center knockout on the top of the enclosure
  • Nine (9) two-stage knockouts for 0.75" or 1" conduit
  • 14.5" (W) x 18" (H) x 4.62" (D)
  • Approximate weight: 15.5 lbs.
Features
  • Enclosure and mounting backplane (included) and 1 or 2 HS4 control units (not included)
  • Removable backplane allows the installer to configure, layout and test prior to on-site installation
Includes
  • Enclosure
  • Power supply
  • Voltage regulator
  • Dual input power distribution module
  • Access power controller
  • Removable mounting backplane
  • One (1) cam lock
  • One (1) Tamper switch
  • Mounting hardware
Notes

VOLTAGE REGULATOR 2-679-0999

  • Voltage Regulator converts a 24VDC input into a regulated 5VDC or 12VDC selectable output at up to 6A supply current
  • Reduces the cost of adding an additional power supply to achieve 24VDC and 12VDC or 5VDC simultaneously
  • DUAL INPUT POWER DISTRIBUTION MODULE 2-679-1100
  • Designed to steer the power from either two (2) low voltage AC or DC power sources
  • Power is distributed over a total of eight (8) fused protected outputs

ACCESS POWER CONTROLLER 2-679-0997

  • Converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs
  • Power outputs can be converted to dry form “C” contacts
  • Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader
  • Keypad, Push Button, PIR, etc., and will route power to a variety of access control hardware devices including Mag Locks, Electric
  • Strikes, Magnetic Door Holders, etc.
  • FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selected for any or all of the four (4) outputs

NOTES: