4500 SURFACE VERTICAL ROD

4500 SVR
ADA Compliant: True
BHMA Certified: True
Hager Lifetime Warranty: True
UL C/US Listed: True
UL Certified EPD: True
Contact Hager for Price

Specifications

Applications

Heavy Duty Commercial

Certifications
  • ANSI/BHMA A156.3-2014 Grade 1
  • UL305 Listed for Panic Hardware
  • UL/cUL Listed for up to 3 hours for "A" label doors up to 10' in height
  • UL10C Positive Pressure Rated
  • UL10B Neutral Pressure Rated
  • Complies with ANSI 117.1 for accessible buildings and facilities
  • Miami-Dade County, Florida NOA #122-0816.08, Exp. Aug. 16, 2027
Cover

Stainless steel, zinc

Cover Tube
Aluminum
Dogging
  • Hex key dogging standard on panic-rated devices
  • Cylinder dogging available on panic rated devices - specify "CD". 3902 Mortise cylinder with standard cam sold separately. Cylinder Length of 1-1/8" (29mm) - 1-3/8" (35mm) is required.
Door Thickness

1-3/4" (44mm) - Standard up to 3", except with night latch which is 2-1/2"

Door Width
  • 36" (914mm) field sizeable to 30" (762mm) panic-rated door and 28" (711 mm) fire-rated door
  • 48" (1219mm) field sizeable to 36" (914mm) panic- or fire-rated door
  • Reference electrified exit device for door width specifications
End Caps
  • Standard end cap (zinc)
  • OPTIONAL Flush end cap (zinc)
Fasteners
  • Wood and machine screws
  • Thru-bolts
Finishes
  • US3, US4, US10B, US26, US26D, US32D, BLK
  • Trim is not available in US32D
Functions

01 - Exit Only (device)

Latchbolt Type
  • Top - 1/2" (13mm) throw, Pullman type with automatic dead-latching, stainless steel
  • Bottom - 1/2" (13mm) throw, Pullman type, held retracted during door swing, stainless steel
Maximum Door Height
  • 7' (2134mm) - Standard
  • 8' (2438mm) Optional
  • 10' (3048mm) Optional (panic device only)
Notes
  • Center line prep is 40". If door prep elevation is lower, a longer rod will need to be ordered.
  • Recommended to be used on appropriately reinforced doors
  • The 4500 SVR tested configuration for Miami-Dade County, Florida NOA #17-1226.23, used a panic threshold with no bottom strike. The suggested Hager part is the 520S but any approved panic threshold can be used. Please see the NOA for further details.
Projection
  • 3" (76mm) in undogged position
  • 2-5/8" (67mm) in dogged position
Push Bar
OPTIONAL Photoluminescent push bar cover available
Rod Length
  • Rods for 7' (2134mm) door - Standard
  • Rods for 8' (2438mm) door Optional
  • Door height of 7' (2134mm) requires 33-1/4" (845mm) top rod length
  • Door height of 8' (2438mm) requires 45-1/4" (1149mm) top rod length
  • Extension rods kits available, 2' (610mm) or 3' (914mm)
Stile Width
  • 5-3/8" (137mm) minimum stile width required for single door and 5/8" (16 mm) stop
  • 4-7/8" (124mm) minimum stile width required for double doors
  • 4-7/8" (124mm) minimum stile width required for double door x Rim device with double door strike
  • All stile widths are measured from door edge
Strikes
  • Stainless steel with plated rollers - Included standard with panic devices
  • Solid stainless steel - Included standard with fire rated devices
  • Surface applied to frame with slotted holes for easy adjustment
  • 10' (3048mm) fire rated device requires strike and hook kit, 4912, for top strike
  • Double door strike for use with surface vertical rod and rim device available
Trim
  • Archer, August, Charles, Johnston, Joshua, Louis, Warren, William or Withnell lever with escutcheon trim
  • Pull plate trim (excluding 45PT)
  • Rim cylinder x optional pull
Warranty

Lifetime

By clicking 'Accept All' you consent that we may collect information about you for various purposes, including: Functionality, Statistics and Marketing