Description: |
- Optional module that is compatible with 2-679-0999
- Allows power to be steered from two (2) independent low voltage 12 or
24 VDC power sources into eight (8) independently controlled fused
protected outputs
- Power outputs can also be converted to dry form "C" contact
- Outputs are activated by an open collector sink or normally open (NO)
dry trigger input from an Access Control System, Card Reader, Keypad,
Push Button, PIR, etc. and will route power to a variety of access control
hardware devices including Mag Locks, Electric Strikes, Magnetic Door
Holders, etc.
- Outputs will operate in both Fail-Safe or Fail-Secure modes
- FACP Interface enables Emergency Egress, Alarm Monitoring, or may be
used to trigger other auxiliary devices. The fire alarm disconnect feature
is individually selectable for any or all of the four (4) outputs
- Fire Alarm disconnect (latching or non-latching) is individually selectable
for any or all of the eight (8) outputs
- Surge suppression
- LED indicators |
Dual Input Access Power Controller
HS4 Power Supplies
Input: |
- Two (2) independent low voltage inputs
- Input 1 and Input 2 voltage range: 5VDC to 24VDC, up to 10A each or 20A total input
|
Output: |
- Fuse protected outputs rated at 2.5A per output, non power-limited
- Total output 20A max (do not exceed the individual power supply ratings)
|
Environmental: |
- Operating temperature: 32°F to 120°F
- Storage temperature: -4°F to 158°F
- Relative humidity 93% +/- 5%
|
Fuse Ratings: |
- Output fuses rated at 2.5A each
- Main input fuses rated at 15A/32V each
|
Dimensions: |
- 7.7" (L) x 4.2" (W) x 1.25" (H)
- Product weight 0.95 lbs
|
Certifications: |
- UL294 Listed - Access Control System Units
- cUL LIsted for CAN/ULC - s319-05, Electronic Access Control Systems
|
Warranty: |
- One (1) year |